邵俊杰等在计算机模拟髋关节活动度的研究中发现,在假体柄颈干角的变化对人工关节活动范围有一定影响。在满足后伸>40°,内收和外展各>50°,外旋>40°,内旋>80°的情况下,颈干角127°股骨假体可以获得的髋关节屈曲度平均为135.64°±3.45°,颈干角131°股骨假体为126°±3.57°,颈干角135°股骨假体为118.29°±3.29°。当然,颈干角越小,偏距越大,可以提高臀中肌的张力,增加髋关节的稳定性。而高偏距假体会在张力侧承受更大的张应力,可能会造成假体或骨水泥套的疲劳断裂,也会因为偏距增加引起股骨假体在髓腔或骨水泥套内产生较高的扭转应力。随着假体材料和设计的改进,各个厂家都推出了高偏距假体,并在临床上得以广泛应用。
参考文献
[1]张国强,王岩.人工关节表面涂层研究现状,中国骨伤2007,20(5):355-358
[2]Bobyn J D,Pilliar R M,Cameron H U.The optimum pore size for the fixation of porous 2 surfaced metal implants by the ingrowth of bone[J].Clin Orthop,1980,150:263-270
[3]郑晓雯,封小建,张延宾.人工股骨柄形状和表面处理对置换术后假体和人体股骨应力分布影响的有限元分析.医用生物力学,2006,(21):4
[4]罗先正,丘贵兴.人工髋关节学[M].北京:中国协和医科大学出版社,2003
[5]林凤飞,郑明,林朝晖.人工髋关节不同材料假体对骨界面的应力分布研究.中国矫形外科杂志,2008,(16):7
[6]Otani T,Whiteside LA,White SE1.The effect of axial and torional loading on strain distribution in the proximal femur as related to cementless total hip arthroplasty.Clin Orthop Relat Res,1993,292:376-383
[7]Xiong D S,Ge S R.Friction and wear properties of UHMWPE/A1203 ceramic under different lubricating conditions.Wear,2001,250(1-12):242
[8]Mcnulty D E,et al.The effect of cross linking UHMWPE on in vitro wear of fixed and mobile bearing knees.ASTM Special Technical Publication,2004,1445:73
[9]Bobyn J D,Pilliar R M,Cameron H U.The optimum pore size for the fixation of porous 2 surfaced metal implants by the ingrowth of bone[J].Clin Orthop,1980,150:263-270
[10]Head W C ,Bauk DJ ,Emerson R H.Titanium as the material of choice for cementless femoral components in total hip arthroplasty[J].Clin Orthop,1995(3112):85-90
[11]Soballe K.Hydroxyapatite ceramic coating for bone implant fixation:mechanical and histological studies in dogs[J].Acta Orthop Scand,1993(Suppl),225:1-58
[12]Pilliar R M,Lee J M,Maniatopoulos C.Observation on the effect of movement on bone ingrowth into porous2surfaced implants[J].Clin Orthop,1986,(208):108-113
[13]盖学周,饶平根,赵光岩,等.人工关节材料的研究进展[J].材料导报,2006,20(1):46-50
[14]Affatato S,Torrecillas R,Taddei P.Advanced nanocomposite materials for orthopaedic applications.I.A long-term in vitro wear study of zirconia-toughened alumina.J Biomed Mater Res B Appl Biomater,2006,78(1):76-82
[15]Cales B.Zirconia as a sliding material:histologic,laboratory,and clinical data.Clin Orthop Relat Res,2000,379:94-112
[16]De Aza AH,Chevalier J,Fantozzi G.Crack growth resistance of alumina,zirconia and zirconia toughened alumina ceramics for joint prostheses.Biomaterials,2002,23(3):937-945
[17]Dowson D,Hardaker C,Flett M.A hip joint simulator study of the performance of metal-onmetal joints:Part Ⅱ:design.J Arthroplasty,2004,19(8 Suppl 3):124-130
[18]Brockett CL,Harper P,Williams S.The influence of clearance on friction,lubrication and squeaking in large diameter metal-on-metal hip replacements.J Mater Sci Mater Med.2008,19(4):1575-1579.
[19]Kluess D,Martin H,Mittelmeier W.Influence of femoral head size on impingement,dislocation and stress distribution in total hip replacement.Med Eng Phys,2007,29(4):465-471
[20]邵俊杰,张先龙,季文婷.髋关节假体安装参数的计算机模拟研究,中华骨科杂志,2008,28(7):552-556
免责声明:以上内容源自网络,版权归原作者所有,如有侵犯您的原创版权请告知,我们将尽快删除相关内容。