由于表面置换采用的假体直径较大,一般在36mm以上,而通常的全髋关节置换术所用的股骨头假体直径为28mm,所以表面置换术后假体的脱位、半脱位的发生率要比普通的全髋置换发生率低。在近几年的临床随访报道中,术后脱位的发生率为0.75%。比利时De Smet曾报道两次脱位都发生在同一患者身上,每次都是因为醉酒后外伤引起,两次都在无麻醉的情况下手法复位成功。Amstutze等报道一例术后50个月由于反复撞击半脱位的患者,最后该患者行翻修全髋置换。表面置换术后脱位的发生主要有两个原因:一是髋臼假体安放位置不良,这也是全髋置换导致脱位的主要原因;二是偏矩过小,这种情况往往发生在股骨头坏死较严重或髋臼发育不良的患者。
偏距的恢复在手术中尤为重要,与人工全髋关节置换不同的是,表面置换缺乏不同规格的头颈尺寸,以满足偏距调节的需求。因此在股骨头顶截骨时,一定要注意股骨头截骨导向器的安放,以恰好覆盖颈部锉骨面为宜,避免安放过深。股骨头顶部过度截骨可以引起偏距短缩,如合并旋转中心内移会引起外展肌松弛,可能导致髋关节不稳定甚至脱位。因此手术中应始终注意软组织的张力。
其他并发症如深静脉血栓、肺栓塞、异位骨化和术中神经血管损伤等与传统全髋置换术相似。
参考文献
[1]王 琦,曾炳芳.髋关节表面置换术.国外医学骨科学分册,2005,26:58-59
[2]张先龙,叶庭均,曾炳芳.髋关节表面置换技术新进展.国外医学骨科学分册,2005,43:1355-1357
[3]Beaule Paul E MD,Campbell Patricia PHD,Shim Paul MD.Femoral Head Blood Flow during Hip Resurfacing.Clinical Orthopaedics&Related Research.POST ACCEPTANCE,2006:28
[4]Long,Jason P BS,Bartel,et al.Surgical Variables Affect the Mechanics of a Hip Resurfacing System.Clinical Orthopaedics&Related Research,2006,453:115-122
[5]Mont,Michael A,Seyler Thorsten M,et al.Use of metal-on-metal total hip resurfacing for the treatment of psteonecrosis of the femoral head.JBJS,2006,88-A(3):90-97
[6]De Smet KA.Pattyn C.Verdonk IL Early result of orimary Birmingham hip resurfacing using a hybrid metal-on-metal couple.Hip Int,2002,12:158-162
[7]Daniel J,Pynsent PB,Mcminn DJW,Metal-onmetal resurfacing of the hip in patients under the age of 55 years with osteoarthritis.JBJS Br,2004,86:177-184
[8]Amstutz HC,Beaul6 PE.Dorey FJ.et a1.Metal-on-metal hybrid surface arthroplasty:two to six-year f0Uow-up study.J Bone Joint Surg Am,2004,86:28-39
[9]Treacy RB,McBryde CW,Pynsent PB.Birmingham hip resurfacing arthroplasty.A minimum follow-up of five years.J Bone Joint Surg Br,2005,87:167-170
[10]Glyn-Jones S,Gill HS,Mclardy-Smith P,et a1.Roentgen stereophotogrammetric analysis of the BirminghalTl hip resurfacing arthroplasty.A two-year study.J Bone Joint Surg Br,2004,86:172-176
[11]Itayem R,Arndt A,Nistor L,et a1.Stability of the Birmingham hip resufacing arthroplasty at two years.A radiostereophotogrammetric analysis study.J Bone Joint Surg Br,2005,87:158-162
[12]Kishida Y.Sugan o N,Nishii T,et a1.Preservation of the bone mineral density of the femar after surface replacement of the hip.J Bone Joint Surg Br,2004,86:185-189
[13]Silva M,Lee KH,Heisel C,et a1.The biomechanical results of total hip resurfacing arthroplasty.J Bone Joint Surg Am,2004,86:40-46
[14]Loughead JM,Chesney D,Hollan d JP,et a1.Comparison of offset in Birminghanl hip resurfacing and hybrid total hip arthroplasty.J Bone Joint Surg Br,2005,87:163-166
[15]Amstutz HC,Beaul PE,Dorey FJ,et a1.Hybrid metal-on-metal surface arthroplasty of the hip.Operative techniques in orthopaedics,2001,11:4
[16]MacDonaid SJ.Metal-on-metal total hip arthroplasty:the concerns.Clin Oahop Relat Res,2004,429:86-93
[17]Chan FW,B0byn JD,Medley JB,et a1.The Otto Aufranc Award.Wear and lubrication of meta1-on-metal hip implants. Clin Orthop Relat Res,1999,369:10-24
[18]Medley JB.Chan FW,ktygier JJ.Comparison of alloys and designs in a hip simulator study of metal on metal implants.C Clin Orthop Relat Res,1996,329(1):148-159
[19]Sieber HP,Rieker CB.Kottig Analysis of l18 second-generation metal-on-metal retrieved hip implants.J Bone Joint Surg Br,1999,81:46-50
[20]Doom PF,Mirra JM ,Campbell PA,et a1.Tissue reaction to metal on metal total hip prostheses.Clin Orthop Relat Res,1996,329(1):187-205
[21]Doom PF,Campbell PA,Worrall J,et a1. Metal wear particle characterization from metal on metal total hip replacements:Transmission electron microscopy study of periprosthetic tissues an disolated particles.J Biomed Mater Res,1998,42:103-l11
[22]Clarke MT,Le ePT,Arora A,et a1.Levels of metal ions after small and large-diameter metalon-metal hip arthmplasty.J Bone Joint Surg Br,2003,85:913-917
[23]Lewis CG,Sunderman FW JL.Metal carcinogenesis in total joint arthroplasty.Animal models.Clin Orthop Relat Res,1996,329(1):264-268
免责声明:以上内容源自网络,版权归原作者所有,如有侵犯您的原创版权请告知,我们将尽快删除相关内容。